KEW 5050 Leakage Current Logger

Availability:

Out of stock


Unpreceded Ior Logger!

  • Provides simultaneous measurements and logs up to 4 channels
  • Supports various wiring systems
    (Single-phase 2&3-wire, Three-phase 3&4-wire*) *Except Ior for 3 Phase 4 wire
  • World’s fastest class speed at 200ms interval for leakage current measurement
  • Offers both traditional leakage / load current measurements
  • Large graphic display and magnet on the back case to attach it on metal enclosures

                       

LKR 993,170

Out of stock

Compare
Wiring configuration 1P2W, 1P3W, 3P3W, 3P4W
Measurements and
parameters
Ior : Leakage current (Trms) with resistive components only
Io : Leakage current (Trms) with basic wave of 50/60Hz only
Iom : Leakage current (Trms) including harmonic components
V : Reference voltage (Trms) with basic wave of 50/60Hz only
Vm : Reference voltage (Trms) including harmonic components
R : Insulation resistance, Frequency(Hz), Phase angle(θ)
Other functions Digital output, Print screen, Backlight, Data hold
Recording Interval 200/400ms/1/5/15/30s/1/5/15/30m/1/2hours
Ior
Range 10.000/100.00/1000.0mA/10.000A/AUTO
Accuracy For reference voltages of sine wave 40 – 70Hz and 90V Trms or higher,
±0.2%rdg±0.2%f.s. + clamp sensor amplitude accuracy + error of phase accuracy*
(phase error)
* add ±2.0%rdg to measured Io value when using Ior leakage clamp sensor.
(θ: within the accuracy of reference voltage/ current phase difference ±1.0°)
Allowable input 1% – 110% (Trms) of each range, and 200% (peak) of the range
Display range 0.15% – 130% (display “0” for less than 0.15%, “OL” if the range is exceeded)
Io *Range, Allowable input and Display Range are the same as Ior .
Accuracy ±0.2%rdg±0.2%f.s.+ clamp sensor amplitude accuracy
Iom *Range, Allowable input and Display Range are the same as Ior .
Accuracy ±0.2%rdg±0.2%f.s.+ clamp sensor amplitude accuracy
Measurement
method
Sampling speed 40.96ksps (every 24.4μs), gapless, calculate Trms values every 200ms.
Voltage
Range 1000.0V
Accuracy ±0.2%rdg±0.2%f.s. * for waveforms of sine wave 40 – 70Hz
Allowable input 10 – 1000V Trms, and 2000V peak
Display range 0.9 – 1100.0V Trms (display “0” for less than 0.9V, “OL” if the range is exceeded)
Phase angle(θ)
Display range 0.0 – ±180.0° (regarding the phase of reference voltage as 0.0°)
Accuracy Within ±0.5° for the inputs of 10% or higher of leakage current range,
sine wave 40 – 70Hz, reference voltage of 90V Trms or higher.
Within ±1.0° when using Ior leakage clamp sensor, and
Within ±0.5°+ clamp sensor accuracy when using general purpose clamp sensor.
Frequency meter range 40 – 70Hz
External supply AC100 – 240V(50/60Hz) 7.5VA max
Power source LR6(AA)(1.5V) × 6 (Battery life approx. 11h)
Display / update period 160 × 160dots, FSTN monochrome display / 500ms
PC card interface SD card (2GB) *standard accessory
Communication
interface
USB
Temperature and
humidity range
23±5°C, relative humidity 85% or less(no condensation)
Operating temperature
and humidity range
-10 – 50°C, relative humidity 85% or less(no condensation)
Storage temperature
and humidity range
-20 – 60°C, relative humidity 85% or less(no condensation)
Applicable Standards IEC 61010-1 CAT Ⅳ 300V / CAT Ⅲ 600V Pollution degree 2
IEC 61010-2-030, IEC 61010-031, IEC 61326
Dimension 165(L) × 115(W) × 57(D)mm
Weight Approx. 680g (including batteries)
Accessories 7273 (Voltage test lead)
8262 (AC adapter)
7278 (Earth cable)
7219 (USB cable)
8326-02 (SD card [2GB])
9125 (Carrying case)
Instruction manual, Cable marker, LR6(AA) × 6
Optional Accessories 8177/8178 (Ior Leakage current Clamp Sensor)
8329 (Power supply adapter)
8121/8122/8123/8124/8125/8126/8127/8128 (Load current Clamp Sensor)*
8130/8133 (Flexible Clamp Sensor)*
8146/8147/8148 (Leakage & Load current clamp sensors)*

Please download “KEW Windows for KEW 5050(software)” from here.

Shows insulation resistance (R) values determined by the following formula.
V: Reference voltage/ Ior: Leakage current
Displayed value is just for reference since the measurement method differs from insulation resistance testers and may not be consistent with each other.
* Cannot be used for Ior measurement.

Ior logger and clamp sensor set model

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “KEW 5050 Leakage Current Logger”

There are no reviews yet.