Month(s) | Handling Fee (%) | Monthly (Approx) | Total (Approx) |
---|---|---|---|
3 | 0.00% | 109,523.67 | 328,571.00 |
6 | 0.00% | 54,761.83 | 328,571.00 |
Month(s) | Handling Fee (%) | Monthly (Approx) | Total (Approx) |
---|---|---|---|
6 | 0.00% | 54,761.83 | 328,571.00 |
Accuracy Specifications | ||
Accuracy specifications are shown as ±(% of reading + number of digits) | ||
DC voltage | Range | 0.1 mV to 1000 V |
Accuracy | ±(0.05% + 1) | |
AC voltage | Range | 0.1 mV to 1000 V |
Accuracy | ±(0.7% + 4) | |
DC current | Range | 0.1 μA to 10 A |
Accuracy | ±(0.2% + 4) | |
AC current | Range | 0.1 μA to 10 A |
Accuracy | ±(1% + 2) | |
Resistance | Range | 0.1 Ω to 50 MΩ |
Accuracy | ±(0.2% + 1) | |
Conductance | Range | 60.00 nS |
Accuracy | ±(1.0% + 10) | |
Diode test | Range | 2.0 V |
Accuracy | ±(2.0% + 1) | |
Duty cycle | Range | 0.0% to 99.9% |
Accuracy | Within ±(0.2% per kHz + 0.1%) for rise times <1 µs | |
Capacitance | Range | 10 nF to 9999 μF |
Accuracy | ±(1% + 2) | |
Frequency | Range | 0.5 Hz to 199.99 kHz |
Accuracy | ±(0.005% + 1) | |
Temperature | Range | -200°C to +1090°C (-328°F to +1994°F) |
Accuracy | ±(1% + 10)°C [±(1% + 10)°F] | |
Display counts | 6000 counts/19,999 counts in high-resolution mode | |
Peak capture | Record transients up to 250 us | |
Min/Max/Avg recording | Display signals up to approximately 100 ms | |
Accuracy specifications are shown as ±(% of reading + number of digits) | ||
Safety Certifications | ||
ATEX | {Ex} II 2G Ex ia IIC T4 Gb | |
{Ex} I M1 Ex ia I Ma | ||
NEC-500 | Class I, Div 1, Groups A-D, 130°C | |
IECEx | Ex ia IIC T4 Gb | |
Ex ia I Ma | ||
GOST R Ex | 1Ex ia IIC T4 Gb X | |
PO Ex ia I Ma X | ||
IP6X | ||
General Specifications | ||
Power | ||
Three AAA batteries | ||
Battery life: 400 hours | ||
Display | LCD, with backlight | |
External protection | Rubber holster | |
Warranty | Three years | |
Size with holster (H x W x L) | 6.4 x 10.0 x 19.8 cm (2.5 x 3.9 x 7.8 in) | |
Weight with holster | 700 g (1.54 lb) |
Now there’s an intrinsically safe digital multimeter (DMM) you can use in a wide range of hazardous settings. Whether you work in petroleum, chemical, or pharmaceutical environments, the 28 II Ex gives high-end test and troubleshooting power you need is packed into the most rugged intrinsically safe (IS) DMM Fluke has ever built: drop-proof, waterproof, dust-proof (IP67). The 28 II Ex meets the following certifications:
IECEx (International)
|
![]() |
ATEX (Europe)
|
![]() |
NEC / CEC (North America)
|
![]() |
PCEC (China)
|
![]() |
Simtars (Australia)
|
![]() |
IEx (Brazil)
|
![]() |
EAC (Russia)
|
![]() |
One tool equips you with all the testing and troubleshooting power you need wherever you go––inside or outside ATEX zones 1 or 2,. No need to carry different meters for different areas, or worry about crossing through an Ex-required zone with a non-Ex rated instrument.
Important extras keep you productive all day long in less than optimal conditions.
Access to the separate battery compartment makes it easy to change batteries or fuses without jeopardizing instrument calibration.
Credit Card
Reviews
There are no reviews yet.