EA15 is an EasyView Dual Input Temperature Datalogger capable of-200 Degrees to 1999 Degrees Fahrenheit and -200 Degree to 1360 Degree Celsius measurements. Timer function displays elapsed time plus the time when minimum and maximum readings are taken. Records Max/Min readings for later recall. Built-in datalogger stores up to 8800 data sets. Complete with built-in stand, protective holster, two Type K bead wire temperature probes and batteries.
Contact Thermometers, Data Loggers, EXTECH, Testing & Measuring, Thermometers
Extech EA15: EasyView™ Dual Input Temperature Datalogger
Availability:
Out of stock
- Dual input thermometer accepts Types J, K, E, T, R, S, and N thermocouples
- Built-in datalogger stores up to 8800 data sets
- RS-232 port to transfer data to PC for analysis (PC software and cable included)
- Compact and rugged design features large backlit display
- Displays [T1 plus T2] or [T1-T2 plus T1] or [T1-T2 plus T2]
- Timer function displays elapsed time plus the time when MIN and MAX readings are taken
- Records Max/Min readings for later recall
- Includes Windows® compatible software and data cable
- Complete with built-in stand, protective holster, two Type K bead wire temperature probes and batteries
LKR 277,200
Out of stock
CompareExtech EA15: EasyView™ Dual Input Temperature Datalogger
Size | |
---|---|
Colour | |
Type |
GENERAL SPECIFICATIONS
- Temperature (Type E) Basic Accuracy
- -200 to 1598 °F (-150 to 870 °C)
- Temperature (Type E) Max Resolution
- ±0.05% of reading (+1.5 °F/+0.75 °C)
- Temperature (Type J)
- 0.1°
- Temperature (Type J) Basic Accuracy
- -200 to 1994 °F (-150 to 1090 °C)
- Temperature (Type J) Max Resolution
- ±0.05% of reading (+1.5 °F/+0.75 °C)
- Temperature (Type K) Basic Accuracy
- 0.1°
- Temperature (Type K) Max Resolution
- -200 to 1999.9 °F (-150 to 1370 °C)
- Temperature (Type N)
- ±0.05% of reading (+1.5 °F/+0.75 °C)
- Temperature (Type N) Basic Accuracy
- 0.1°
- Temperature (Type N) Max Resolution
- -200 to 1999.9 °F (-150 to 1300 °C)
- Temperature (Type R)
- ±0.05% of reading (+1.5 °F/+0.75 °C)
- Temperature (Type R) Basic Accuracy
- 0.1°
- Temperature (Type R) Max Resolution
- 35 to 1999.9 °F (2 to 1767 °C)
- Temperature (Type S)
- ±0.05% of reading (+4 °F/+2 °C)
- Temperature (Type S) Basic Accuracy
- 0.1°
- Temperature (Type S) Max Resolution
- 35 to 1999.9 °F (2 to 1767 °C)
- Temperature (Type T)
- ±0.05% of reading (+4 °F/+2 °C)
- Temperature (Type T) Basic Accuracy
- 0.1°
- Temperature (Type T) Max Resolution
- -200 to 752 °F (-150 to 400 °C)
- Temperature [IR]
- ±0.05% of reading (+1.5 °F/+0.75 °C)
- Temperature [Type K]
- 0.1
There are no reviews yet.