Colour | |
---|---|
Size |
AC A | 60.00/600.0/1000A (Auto-ranging) Ā±1.5%rdgĀ±4dgt [45 – 65Hz] Ā±2.0%rdgĀ±5dgt [40 – 1kHz] |
---|---|
AC V | 60.00/600.0V (Auto-ranging) Ā±1.0%rdgĀ±2dgt [45 – 65Hz] (600V) Ā±1.5%rdgĀ±4dgt [40 – 1kHz] (60/600V) |
DC V | 60.00/600.0V (Auto-ranging) Ā±1.0%rdgĀ±3dgt (60V) Ā±1.2%rdgĀ±3dgt (600V) |
Ī© | 600.0Ī©/6.000/60.00/600.0kĪ©/6.000/40.00MĪ©(Auto-ranging) Ā±1.0%rdgĀ±5dgt (600Ī©) Ā±2.0%rdgĀ±3dgt (6/60/600kĪ©) Ā±3.0%rdgĀ±3dgt (6MĪ©) Ā±5.0%rdgĀ±3dgt (40MĪ©) |
Continuity buzzer | 600Ī© (Buzzer sounds below 90Ī©) |
Capacitance test | 1.000/10.00/100.0Ī¼F Ā±3.0%rdgĀ±15dgt(1Ī¼F) Ā±3.0%rdgĀ±10dgt(10/100Ī¼F) |
Diode test | 2.000V Ā±4%rdgĀ±5dgt Open-circuit voltage:<3.5V |
Hz | 999.9Hz/9.999kHz (Auto-ranging) Ā±0.1%rdgĀ±3dgt (Input sensitivity Current:more than 4A Voltage:more than 2V) |
Conductor size | Ļ33mm max. |
Applicable standards | IEC 61010-1 CAT ā
£ 300V, CAT ā
¢ 600V Pollution degree 2 IEC 61010-031, IEC 61010-2-032, IEC 61010-2-033, IEC 61326-2-2(EMC), IEC 60529 IP40, EN 50581(RoHS) |
Power source | R03/LR03(AAA)(1.5V)x2 |
Continuous measuring time | approx. 170 hours (when R03 is used)(NCV_LED, Backlight:off) (Auto power save : approx.10 minutes) |
Dimensions | 204(L) Ć 81(W) Ć 36(D)mm |
Weight | 230g Approx. (including batteries) |
Included Accessories | 7066A (Test leads), 9079 (Carrying case), R03(AAA)Ć2, Instruction manual |