| Wiring configuration | 1P2W, 1P3W, 3P3W, 3P4W | |
|---|---|---|
| Measurements and parameters |
Ior : Leakage current (Trms) with resistive components only Io : Leakage current (Trms) with basic wave of 50/60Hz only Iom : Leakage current (Trms) including harmonic components V : Reference voltage (Trms) with basic wave of 50/60Hz only Vm : Reference voltage (Trms) including harmonic components R : Insulation resistance, Frequency(Hz), Phase angle(θ) |
|
| Other functions | Digital output, Print screen, Backlight, Data hold | |
| Recording Interval | 200/400ms/1/5/15/30s/1/5/15/30m/1/2hours | |
| Ior | ||
| Range | 10.000/100.00/1000.0mA/10.000A/AUTO | |
| Accuracy | For reference voltages of sine wave 40 to 70Hz and 90V Trms or higher, ±0.2%rdg±0.2%f.s. + clamp sensor amplitude accuracy + error of phase accuracy* (phase error) * add ±2.0%rdg to measured Io value when using Ior leakage clamp sensor. (θ: within the accuracy of reference voltage/ current phase difference ±1.0°) |
|
| Allowable input | 1% to 110% (Trms) of each range, and 200% (peak) of the range | |
| Display range | 0.15% to 130% (display “0” for less than 0.15%, “OL” if the range is exceeded) | |
| Io *Range, Allowable input and Display Range are the same as Ior . | ||
| Accuracy | ±0.2%rdg±0.2%f.s.+ clamp sensor amplitude accuracy | |
| Iom *Range, Allowable input and Display Range are the same as Ior . | ||
| Accuracy | ±0.2%rdg±0.2%f.s.+ clamp sensor amplitude accuracy | |
| Measurement method |
Sampling speed 40.96ksps (every 24.4μs), gapless, calculate Trms values every 200ms. | |
| Voltage | ||
| Range | 1000.0V | |
| Accuracy | ±0.2%rdg±0.2%f.s. * for waveforms of sine wave 40 to 70Hz | |
| Allowable input | 10 to 1000V Trms, and 2000V peak | |
| Display range | 0.9 to 1100.0V Trms (display “0” for less than 0.9V, “OL” if the range is exceeded) | |
| Phase angle(θ) | ||
| Display range | 0.0 to ±180.0° (regarding the phase of reference voltage as 0.0°) | |
| Accuracy | Within ±0.5° for the inputs of 10% or higher of leakage current range, sine wave 40 to 70Hz, reference voltage of 90V Trms or higher. Within ±1.0° when using Ior leakage clamp sensor, and Within ±0.5°+ clamp sensor accuracy when using general purpose clamp sensor. |
|
| Frequency meter range | 40 to 70Hz | |
| External supply | AC100 to 240V(50/60Hz) 7.5VA max | |
| Power source | LR6(AA)(1.5V) × 6 (Battery life approx. 11h) | |
| Display / update period | 160 × 160dots, FSTN monochrome display / 500ms | |
| PC card interface | SD card (2GB) *standard accessory | |
| Communication interface |
USB | |
| Temperature and humidity range |
23±5°C, relative humidity 85% or less(no condensation) | |
| Operating temperature and humidity range |
-10 to 50°C, relative humidity 85% or less(no condensation) | |
| Storage temperature and humidity range |
-20 to 60°C, relative humidity 85% or less(no condensation) | |
| Applicable Standards | IEC 61010-1 CAT Ⅳ 300V / CAT Ⅲ 600V Pollution degree 2 IEC 61010-2-030, IEC 61010-031, IEC 61326 |
|
| Dimension | 165(L) × 115(W) × 57(D)mm | |
| Weight | Approx. 680g (including batteries) | |
| Accessories | 7273 (Voltage test lead) 8262 (AC adapter) 7278 (Earth cable) 7219 (USB cable) 8326-02 (SD card [2GB]) 9125 (Carrying case) Instruction manual, Cable marker, LR6(AA) × 6 |
|
| Optional Accessories | 8177/8178 (Ior Leakage current Clamp Sensor) 8329 (Power supply adapter) 8121/8122/8123/8124/8125/8126/8127/8128 (Load current Clamp Sensor)* 8130/8133 (Flexible Clamp Sensor)* 8146/8147/8148 (Leakage & Load current clamp sensors)* |
|
Please download “KEW Windows for KEW 5050(software)” from here.
Shows insulation resistance (R) values determined by the following formula.
V: Reference voltage/ Ior: Leakage current
Displayed value is just for reference since the measurement method differs from insulation resistance testers and may not be consistent with each other.
* Cannot be used for Ior measurement.
*Included accessories for below models are same with above-mentioned.
Credit Card
Marlbo Assistant • Online
Reviews
There are no reviews yet.