KYORITSU KEW 6041BT INSULATION EARTH TESTER

In Stock

KYORITSU KEW 6041BT INSULATION EARTH TESTER

Be released from test lead problems!
Three testing functions in a palm sized tester

  • Possible to measure line voltage up to 440 V
  • Small test current of 2 mA or less prevents unintentional RCD trip. (on EARTH function)
  • Live circuit warning (on INSULATION and EARTH functions)
  • Comparator function with audible warning
  • Setting customization via app
  • Enable/disable unnecessary functions or ranges.
    Any desired max displayed value and threshold value for comparator are selectable.
  • Replaceable 4-type of metal tips are available.
    Standard, long, and molded metal tips (accessories)
    L-shaped probe useful in high place measurement (optional accessory)
  • Bluetooth® communication
    Save the measured values in tablets or smartphones.

             

             

     

Easy Payment Plans

Sampath Bank Payment Plans
The installment payment calculations now include the VAT(18%) amount of Rs.0.00, bringing the total cost to Rs.0.00. All displayed amounts reflect this inclusive pricing for complete transparency.
Month(s) Handling Fee (%) Monthly (Approx) Total (Approx)
3 0.00% 0.00 0.00
6 0.00% 0.00 0.00
12 0.00% 0.00 0.00

Specification

Insulation resistance

Rated voltage 50 V 125 V 250 V 500 V
Range 2.000/20.00/200.0 MΩ(Auto-ranging)
First effective range
Measuring range 0.100 to 10.00 MΩ 0.100 to 25.0 MΩ 0.100 to 50.0 MΩ 0.100 to 100.0 MΩ
Mid-scale value 1 MΩ 2 MΩ 2 MΩ 5 MΩ
Accuracy ±2%rdg±2dgt
Second effective range
Measuring range 0.050 to 0.099 MΩ
Accuracy ±2%rdg±4dgt
Measuring range 10.01 to 200.0 MΩ 25.1 to 200.0 MΩ 50.1 to 200.0 MΩ 100.1 to 200.0 MΩ
Accuracy ±5%rdg
Other range
Measuring range 0.000 to 0.049 MΩ
Accuracy ±2%rdg±6dgt
Rated current 1.0 to 1.2 mA(at the following resistances)
0.050 MΩ 0.125 MΩ 0.250 MΩ 0.500 MΩ
Open-circuit voltage 100 to 120% of rated voltage
Short-circuit current 1.5 mA or less
Earth resistance
Measuring range 200.0/2000 Ω(Auto-ranging)
Accuracy ±3%rdg±5dgt
Output current Approx. 1.6 mA(200 Ω range)/825 Hz, Approx. 0.7 mA(2000 Ω range)/825 Hz
Volt
Measuring range 2.0 to 440.0 V AC/±2.0 to ±440.0 V DC (AC/DC auto-detection: 2 V or higher)
Accuracy ±1%rdg±4dgt AC/±1%rdg±8dgt DC
Applicable standards IEC 61010-1, IEC 61010-2-030 CAT Ⅳ 150 V/CAT Ⅲ 300 V Pollution degree 2,
IEC 61010-2-034, IEC 61557-1,2,5,10,  IEC 60529(IP40), IEC 61326-1, IEC 61326-2-2, IEC 61010-031
Communication interface Bluetooth® 5.0
Operating temperature and humidity range -10 to 50 °C, relative humidity 85% or less(no condensation)
Storage temperature and
humidity range
-20 to 60 °C, relative humidity 75% or less(no condensation)
Power source LR6(AA)(1.5 V) x 2
Dimension 232(L) x 51(W) x 42(D) mm(including the tip metal parts)
Weight Approx. 230 g(including batteries)
Accessories 7248 (Test lead with alligator clip and flat test probe)
8072A (CAT Ⅱ standard prod)
8017B (Extension prod long)
8253 (CAT Ⅲ standard prod)
9161 (Carrying case)
Batteries, Instruction manual
Optional accessories 7296 (L-shaped probe set)
9198 (Carrying case for L-shaped probe)

Product Overview

Insulation resistance measurement

  • 4 ranges (50/125/250/500 V)
  • Warning with red LCD backlight for high voltage 500 V range
  • Auto-discharge function
    Charged voltages are automatically discharged after measurement.
  • Live circuit warning
    Safety design-Audible warning and red LCD backlight indicate the measured voltage is higher than the reference value, and no measurement is performable.
  • Comparator function
    Audible warning and red LCD backlight indicate the measured voltage drops below the reference value.
    (Reference value is changeable via special app.)
Rated voltage 50 V 125 V 250 V 500 V
Reference value 0.100 MΩ 0.100 MΩ 0.200 MΩ 0.400 MΩ

*At the shipment

Earth resistance measurement

  • 200/2000 Ω Auto-ranging
  • Small test current of 2 mA or less prevents unintentional RCD trip
  • Live circuit warning
    Audible warning and red LCD backlight indicate that the measured voltage is 30 V or higher; during this time, no measurement can be performed.
  • Comparator function
    Audible warning and red LCD backlight indicate that the measured voltage is higher than the reference value.
    (Reference value is changeable via special app.)

*Helpful method when auxiliary earth electrodes aren’t able to be driven into the ground.
This is a simplified earth resistance tester and uses the existing earth systems (with a sufficiently low earth resistance) such as buried metal pipes like main water pipe, common earth for commercial power supply and a lightning electrode on buildings and performs measurements based on the 2-pole measurement method.

Earth resistance measurement of load

Earth resistance measurement of outlet

 

Voltage measurement

  • Measurable up to 440 V max.
  • True RMS measurement even on distorted waveforms
  • AC/DC auto-detection

Illuminance sensor installed. Facilitates work in dimly lit areas.

  • LED light and LCD backlight with automatic on/off function
  • Glow-in-the-dark switches

 

 

Measurement Data Management Application KEW Smart Advanced

ダミーイメージ

Measurement Data Management Application “KEW Smart Advanced” supporting Android™ and iOS

For details, click here.

 

Customize certain product’s settings through the app (for KEW 6041BT only)

Change of Comparator function
(for Insulation and Earth resistance)

Possible to turn ON/OFF comparator function or change threshold value for warning.

Quick reset of settings is possible.

Suddenly need to use any of the disabled feature, press the power switch with holding down the SELECT switch and restart it. This temporarily restores settings to the default. Default Reset is possible without using the app.

*This is a temporary setting. To reset settings changed via the app and completely initialized (restore to factory default setting), extra operations are required.

 

Change of Maximum measurement display value

Maximum display value of voltage, insulation and earth resistance can be set to the desired value.

E.g.: Max resistance value on 250 V range for insulation resistance measurement is changed to 10 MΩ.

Enable/Disable Setting Function

Prevent unintentional output on insulation ranges! Disable unnecessary features!

E.g.: Voltage measurement and 50 V and 500 V are disabled.

*Even when the voltage function is turned off, voltage can be measured while the insulation and earth resistance functions are in stand-by mode.

Reviews

There are no reviews yet.

Be the first to review “KYORITSU KEW 6041BT INSULATION EARTH TESTER”

Your email address will not be published. Required fields are marked *

Related Products

In Stock

KYORITSU KEW 6041BT INSULATI...

Out of stock

Fluke 1670 Series Multifunct...

In Stock

KEW 6315 POWER QUALITY ANALY...
LKR 1,872,910

Out of stock

KEW 5050 Ior LOGGER
LKR 1,072,570

Out of stock

Fluke 6500-2 Portable Applia...

Out of stock

KEW 3025B HIGH VOLTAGE INSUL...
LKR 268,850

In Stock

KEW 1020R DIGITAL MULTIMETER
LKR 47,350

Out of stock

Fluke 1587 FC Insulation Mul...
LKR 1,007,930

Out of stock

SMFT-1000 Solar Tools Kit: F...
LKR 2,922,905

Out of stock

KEW 4105A-H EARTH TESTER
LKR 182,050

Product Search

Request Quote