KEW 1052

Availability:

Out of stock


High Accuracy, High Performance and Reliable Measurements
• 0.09% basic DC accuracy
• Large display with 6,000 counts
• True-RMS Measurements
• True-RMS or MEAN value detection mode can be selected
• Low-pass filter for motor drive measurements
• User calibration function

Safety design for industrial use
• Complies with IEC 61010-1 CAT IV 600V , CAT III 1000V
• Terminal shutter to prevent incorrect test leads’ insertion in current terminals
• Very wide operating temperature range from -10 to 55ºC

Reliable support for data management
• Large data internal memory 1,600 data (logging), 100 data (manual)
• Download data and Live Monitoring on a PC via the USB interface
(Option for USB Communication set)
*MAX 32,767 data can be transferred.

Product Catalogue

TRUE RMS     CAT4 600V    DCACV    DCACA    Resistance    Continuitybuzzer    Diode    Capacitance

Frequency    Temperature    Backlight  DATAHOLD     MAX/MIN/AVG    Filter      USB    AutoPowerOff

LKR 188,091

Out of stock

Compare

KEW 1052

Colour
Size
Type
Detection mode MEAN/RMS (switch)
DC V 600.0mV/6.000/60.00/600.0/1000V
(Input impedance: 10MΩ [600mV/60/600/1000V], 11MΩ [6V])
±0.09%rdg±2dgt (Basic accuracy)
AC V [RMS] 600.0mV/6.000/60.00/600.0/1000V
(Input impedance: 10MΩ<200pF [600mV], 11MΩ<50pF [6V],
10MΩ<50pF [60/600/1000V])
±0.5%rdg±5dgt (Basic accuracy)
AC V [MEAN] 600.0mV/6.000/60.00/600.0/1000V
(Input impedance: 10MΩ<200pF [600mV], 11MΩ<50pF [6V],
10MΩ<50pF [60/600/1000V])
±0.5%rdg±5dgt (Basic accuracy)
DC A 600.0/6000µA/60.00/440.0mA/6.000/10.00A
±0.2%rdg±2dgt (Basic accuracy)
AC A [RMS] 600.0/6000µA/60.00/440.0mA/6.000/10.00A
±0.75%rdg±5dgt (Basic accuracy)
Ω 600.0Ω/6.000/60.00/600.0kΩ/6.000/60.00MΩ
±0.4%rdg±1dgt (Basic accuracy)
Continuity buzzer 600.0Ω (The buzzer turns on for resistances lower than 50±30Ω)
Diode test 2.000V ±1%rdg±2dgt
Open curcuit voltage: <3.5V (Approx. 0.5mA Measuring Current)
Capacitance 10.00/100.0nF/1.000/10.00/100.0/1000µF
±2%rdg±5dgt (Basic accuracy)
Frequency 10.00 – 99.99/90.0 – 999.9Hz/0.900 – 9.999/9.00 – 99.99kHz
±0.02%rdg±1dgt (Basic accuracy)
Temperature -50 – 600ºC ±2%rdg±2ºC (with the use of K-type Temperature probe)
Other functions Data Hold (D/H), Auto Hold (A/H), Range Hold (R/H),
Maximum value (MAX) *, Minimum value (MIN) *, Average value (AVG) *, Zero Adjustment (Capacitor, Resistance), Save to Memory *,
LCD backlight
Applicable standards IEC 61010-1 CAT IV 600V, CAT III 1000V Pollution degree 2,
IEC 61010-031, IEC 61326-1 (EMC)
Power source R6 (1.5V)×4 (Auto power off: approx. 20 minutes)
Dimensions 192(L)×90(W)×49(D) mm
Weight Approx. 560g (including batteries)
Included Accessories 7220A (Test leads), R6×4, Instruction manual,
8926 (Fuse [440mA/1000V])×1 (included)
8927 (Fuse [10A/1000V])×1 (included)
Option
Description Model Specification
Crocodile clip test lead 7234 CAT IV 600V, CAT III 1000V
AC/DC Clamp Sensor 8115 AC 130A / DC 180A
Clamp sensor 8121 AC 100A
8122 AC 500A
8123 AC 1000A
8146 AC 30A
8147 AC 70A
8148 AC 100A
Banana Ø4mm Adjuster Plug 7146 length:190mm
USB Communication set 8241 USB adaptor + USB cable + DMM Software
Carrying case 9154 for the main unit with testi leads and communication cable
Thermocouple Type K Specification
Description Model Specification
Temperature probes 8405 -40ºC – 500ºC
(Surface type, Point material: Ceramic)
8406 -40ºC – 500ºC (Surface type)
8407 -40ºC – 700ºC (Liquid, Semi-solid)
8408 -40ºC – 600ºC (Air, Gas)

Based on 0 reviews

0.0 overall
0
0
0
0
0