3 channel inputs for the simultaneous recording of Leakage Current and Load Current
Click here to download DATA SHEET
LKR 294,035
Out of stock
Month(s) | Handling Fee (%) | Monthly (Approx) | Total (Approx) |
---|---|---|---|
3 | 0.00% | 115,653.57 | 346,960.71 |
6 | 0.00% | 57,826.79 | 346,960.71 |
Month(s) | Handling Fee (%) | Monthly (Approx) | Total (Approx) |
---|---|---|---|
6 | 0.00% | 57,826.79 | 346,960.71 |
Range | RMS Accuracy |
---|---|
100.0mA | ±2.0%rdg±0.9%f.s.+ Accuracy of Sensor |
Other ranges | ±1.5%rdg±0.7%f.s.+ Accuracy of Sensor |
Crest Factor | 2.5 or less: RMS accuracy (sine) + 2%rdg + 1%f.s. |
*Max, Min and Instant Peak values in Normal Recording mode are just reference values:
their accuracies aren't guaranteed.
Range | Accuracy |
---|---|
100.0mA | ±3.5%rdg±2.2%f.s.+ Accuracy of Sensor |
Other ranges | ±3.0%rdg±2.0%f.s.+ Accuracy of Sensor |
Range | Accuracy |
---|---|
100.0mA | ±3.0%rdg±1.7%f.s.+ Accuracy of Sensor |
Other ranges | ±2.5%rdg±1.5%f.s.+ Accuracy of Sensor |
Recording mode | Normal, Trigger, Capture |
---|---|
Operating system | Successive Approximation (CH1 single synchronized sampling) |
Rated max. working voltage | AC 9.9Vrms, 14V peak value |
Number of input channel | 3ch |
Measuring method | True RMS |
RMS measuring interval | Approx. 100ms |
Sampling interval | Normal/Trigger mode : Approx. 1.65ms/CH Capture mode : Approx. 0.55ms (waveform: at every 1.1ms) |
Current range | 8146 (30A type) : 100.0/1000mA/10.00/30.0A 8147 (70A type) : 100.0/1000mA/10.00/70.0A 8148 (100A type) : 100.0/1000mA/10.00/100.0A 8121 (100A type) : 10.00/100.0A 8122 (500A type) : 50.00/500.0A 8123 (1000A type) : 100.0/1000A 8128/8135 (5A type) : 5.000A/(50.00A) 8127 (100A type) : 10.00A/100.0A 8126 (200A type) : 20.00A/200.0A 8125 (500A type) : 50.00A/500.0A 8124 (1000A type) : 100.0A/1000A 8130 (1000A type) : 100.0/1000A |
Low battery warning | Battery mark display (in 4 levels) |
Over-range indication | "OL" mark is displayed when exceeding the measuring range |
Auto power off | Turns off the instrument automatically if there is no switch operation for about 3 min. (This function doesn’t work during a recording.) |
Possible measurement time | Approx. 10 days (with alkaline LR6 batteries) |
Applicable standards | IEC 61010-1:2001 CAT Ⅲ 300V Pollution degree2, IEC 61326 (EMC) |
Dimension | 111(L)×60(W)×42(D)mm |
Weight | Approx. 265g |
Accessories | 7148 (USB cable) 9118 (Carrying case) LR6×4pcs Instruction manual Quick manual USB Notice sheet |
Optional Accessories | 8146/8147/8148 (Leakage & Load current Clamp Sensor) 8121/8122/8123 (Load current Clamp Sensor) 8124/8125(*1)/8126(*2)/8127(*3)/8128 (Load current Clamp Sensor) 8130(*4)/8135 (Flexible Clamp Sensor) 7185 (Extension cable for sensor) 8320 (AC Adapter) 9135 (Carrying bag) |
Please download “KEW LOG Soft2(software)” from here.
*1-4: Can use with after the following serial numbers.
*1:8125 No.02637-
*2:8126 No.00151-
*3:8127 No.00181-
*4:5010 No.8029792-
For monitoring power line status or an intermittent leakage.
For observing an irregular operation of an ELCB/RCD, an irregular current.
For observing waveforms easily.
60,000 data points can be recorded when 1ch is used, and when all the three channels are used, 20,000 data points per channel can be recorded.
MAX.number of recorded data
Using all 3 channels | Using 2 channels | Using only 1 channel |
---|---|---|
20,000 data | 30,000 data | 60,000 data |
Max. recording duration
Recording interval |
Using all 3 channels | Using 2 channels | Using only 1 channel |
---|---|---|---|
1 sec. | 5:33:20 | 8:20:00 | 16:40:00 |
2 sec. | 11:06:40 | 16:40:00 | 1 day 9:20:00 |
5 sec. | 1 day 3:46:40 | 1 day 17:40:00 | 3 days 11:20:00 |
10 sec. | 2 days 7:33:20 | 3 days 11:20:00 | 6 days 22:40:00 |
15 sec. | 3 days 11:20:00 | 5 days 5:00:00 | 10 days 10:00:00 |
20 sec. | 4 days 15:06:40 | 6 days 22:40:00 | 13 days 21:20:00 |
30 sec. | 6 days 22:40:00 | 10 days 10:00:00 | 20 days 20:00:00 |
1 min. | 13 days 21:20:00 | 20 days 20:00:00 | 41 days 16:00:00 |
2 min. | 27 days 18:40:00 | 41 days 16:00:00 | 83 days 8:00:00 |
5 min. | 69 days 10:40:00 | 104 days 4:00:00 | 208 days 8:00:00 |
10 min. | 138 days 21:20:00 | 208 days 8:00:00 | 416 days 16:00:00 |
15 min. | 208 days 8:00:00 | 260 days 10:00:00 | 520 days 0:00:00 |
20 min. | 277 days 18:40:00 | 416 days 16:00:00 | 833 days 8:00:00 |
30 min. | 416 days 16:00:00 | 625 days 0:00:00 | 1250 days 0:00:00 |
60 min. | 833 days 8:00:00 | 1250 days 8:00:00 | 2500 days 0:00:00 |
Continuous measuring time : Approx. 10 days (Alkaline Battery)
* Max recording time is dependent on battery life (approx 10-days with Alkaline battery)
* Use of optional AC Adopter is recommended for long time recording.
Credit Card