KEW 6024PV

Availability:

In stock


• Correct measuring for Insulation resistance even if the panel is under generating power
• Waterproof design: Can measure under the bad weather condition
• Memory function up to 1000 data
• Luminescence button and Backlight

Product Catalogue

LKR 376,685

In stock

Compare

KEW 6024PV

Size
Colour
Insulation resistance PV insulation Insulation
Test voltage 500V 1000V 250V 500V 1000V
Measuring range
(Auto range)
20.00/200.0/2000MΩ 20.00/200.0/2000MΩ
Mid-scale value 50MΩ
Rated current 1.0-1.2mA
0.25MΩ 0.5MΩ 1MΩ
First effective
measuring range
1.51-200.0MΩ 1.51-1000MΩ 1.51-100.0MΩ 1.51-200.0MΩ 1.51-1000MΩ
Accuracy ±1.5%rdg±5dgt ±1.5%rdg±5dgt
Second effective
measuring range
0.00-1.50MΩ 0.00-1.50MΩ 1.20-1.50MΩ 1.20-1.50MΩ 1.20-1.50MΩ
200.1-2000MΩ 1001-2000MΩ 100.1
-2000MΩ
200.1
-2000MΩ
1001
-2000MΩ
Accuracy ±5.0%rdg±6dgt
Open circuit voltage 0 – +20%
Short circuit current Max 1.5mA
Earth resistance
Measuring range
(Auto range)
20.00/200.0/2000Ω
Accuracy ±3.0%rdg±0.1Ω (20Ωrange) ±3.0%rdg±3dgt (200/2000Ωrange)
Voltage measurement
Measuring range AC 5-600V (45-65Hz)DC ±5-±1000V
Accuracy ±1.0%rdg±4dgt
General
Applicable Standards IEC 61010-1 CAT Ⅲ 600V, CAT IV 300V Pollution2
IEC 61010-2-030, IEC 61010-031(EMC), IEC 60529(IP54),
IEC 61557-1,-2,-5,-10, IEC 61326-1,2-2, EN50581(RoHS)
Power source LR6(AA)(1.5V) x 6
Dimensions /
Weight
84(L) x 184(W) x 133(D)mm / Approx. 900g (including batteries)
Accessories 7196B(Test leads with remote control switch),
7244A(Test lead with alligater clip), 8017(Extension prod),
8072(CAT II standard prod),
8212-USB(USB adaptor with “KEW Report (Software)”),
9155(Shoulder strap), 9156A(Carrying case), LR6x6, Instruction manual
Optional 7243A(L-shaped probe), 7245A(Precision measurement cord set),
8016(Hook type prod)

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “KEW 6024PV”