LKR 802,170
In stock
Month(s) | Handling Fee (%) | Monthly (Approx) | Total (Approx) |
---|---|---|---|
3 | 0.00% | 315,520.20 | 946,560.60 |
6 | 0.00% | 157,760.10 | 946,560.60 |
Month(s) | Handling Fee (%) | Monthly (Approx) | Total (Approx) |
---|---|---|---|
6 | 0.00% | 157,760.10 | 946,560.60 |
Insulation resistance | SPD (Varistor) |
||||||
---|---|---|---|---|---|---|---|
Test voltage | 100V | 250V | 500V | 1000V | Max.1000V | ||
Measuring ranges | 2.000/20.00/200.0MΩ (Auto-ranging) |
20.00/200.0/ 1000MΩ (Auto-ranging) |
20.00/200.0/ 2000MΩ (Auto-ranging) |
0 to 1049V (goes up by 1V) |
|||
Accuracy | ±2%rdg±6dgt (2.000/20.00MΩ) ±5%rdg±6dgt (200.0MΩ) |
±2%rdg±6dgt (20.00/200.0MΩ) ±5%rdg±6dgt (1000MΩ) |
±2%rdg±6dgt (20.00/200.0MΩ) ±5%rdg±6dgt (2000MΩ) |
±5%rdg±5dgt | |||
Rated current | 1.0 to 1.2mA @0.1MΩ |
1.0 to 1.2mA @0.25MΩ |
1.0 to 1.2mA @0.5MΩ |
1.0 to 1.2mA @1MΩ |
‐ | ||
Output short circuit current | 1.5mA max | ‐ | |||||
Loop impedance | |||||||
Function | LOOP ATT | LOOP HIGH | |||||
L-PE/L-N (3wire) |
L-PE (2wire) |
L-PE (0.01ΩRes) |
L-PE (0.001ΩRes) High test current (25A) |
L-N/L-L | |||
Rated voltage | 100 to 260V (50/60Hz) |
48 to 260V (50/60Hz) |
48 to 260V (50/60Hz) |
100 to 260V (50/60Hz) |
48 to 500V (50/60Hz) |
||
Impedance range | 20.00/200.0/2000Ω (Auto-ranging) |
20.00/200.0/2000Ω (Auto-ranging) |
2.000Ω | 20.00Ω | |||
Accuracy | ±3%rdg±6dgt | ±3%rdg±10dgt | ±3%rdg±4dgt | ±3%rdg±25mΩ | ±3%rdg±4dgt | ||
Nominal test current at 0Ω external loop: Magnitude/ Duration at 230V |
L-N:6A/60ms N-PE:10mA |
L-PE:15mA | 20Ω: 6A/20ms 200Ω: 0.5A/20ms 2000Ω: 15mA/500ms |
25A/20ms | 6A/20ms | ||
PSC/PFC | |||||||
Range | 2000A/20kA (L-N(PSC)/L-PE(PFC)) |
2000A/20kA (PFC) |
2000A/20kA (PFC) |
2000A/50kA (PFC) |
2000A/20kA (PSC) |
||
Accuracy | PSC/PFC accuracy is derived from measured loop impedance specification and measured voltage specification | ||||||
RCD | |||||||
Rated voltage | 100 to 260V(50/60Hz) | ||||||
Function | x1/2, x1,x5,Ramp,Auto,Uc | ||||||
6/10/30/100/300/500/1000mA/variable | |||||||
RCD type | AC(G/S) | A(G/S) | F(G/S) | B(G/S) | EV | ||
Trip current setting | x1/2, x1,Uc |
10/30/100/300/ 500/1000mA(G) 10/30/100/ 300/500(S) |
10/30/100/ 300/500mA |
10/30/100/ 300/500mA |
10/30/100/ 300mA |
6mA (x1 only) |
|
x5 | 10/30/100mA | 10/30/100mA | 10/30/100mA | 10/30mA | - | ||
Ramp | 10/30/100/ 300/500mA |
10/30/100/ 300/500mA |
10/30/100/ 300/500mA |
10/30/100/ 300mA |
6mA | ||
Accuracy | Trip current |
x1/2 | -8 to -2% | -10 to 0% | -10 to 0% | -10 to 0% | - |
x1 | +2 to +8% | 0 to +10% | 0 to +10% | 0 to +10% | 0 to +10% | ||
x5 | +2 to +8% | 0 to +10% | 0 to +10% | 0 to +10% | - | ||
Ramp | -4 to +4% | -10 to +10% | -10 to +10% | -10 to +10% | -10 to +10% | ||
Trip time |
x1/2 | 2000ms(G/S):±1%rdg±2ms | - | ||||
x1 | 550ms(G):±1%rdg±2ms,1000ms(S):±1%rdg±2ms | 10.5s:±1%±2㎳ | |||||
x5 | 410ms(G/S):±1%rdg±2ms | - | |||||
Continuity | |||||||
Range | 20.00/200.0/2000Ω (Auto-ranging) | ||||||
Open circuit voltage(DC) | 7 to 14V | ||||||
Measuring current |
200mA | 200mA or more(2Ω or less) | |||||
15mA | 15mA±3mA(short-circuit) | ||||||
Accuracy | ±2%rdg±8dgt | ||||||
Volts | |||||||
Range | 300.0/600V(Auto-ranging) | ||||||
Measuring ranges |
Volts | 2 to 600V | |||||
Frequency | 45 to 65Hz | ||||||
Accuracy | Volts | ±2%rdg±4dgt | |||||
Frequency | ±0.5%rdg±2dgt | ||||||
Phase Rotation | |||||||
Rated voltage | 48 to 600V(45 to 65Hz) | ||||||
Remarks | Remarks Correct phase sequence: are displayed “1.2.3” and mark Reversed phase sequence: are displayed “3.2.1” and mark |
||||||
Earth | |||||||
Range | 20.00/200.0/2000Ω(Auto-ranging) | ||||||
Accuracy | ±2%rdg±0.08Ω(20.00Ω) ±2%rdg±3dgt(200.0/2000Ω) |
||||||
General | |||||||
Applicable standards | IEC 61010-1 CAT IV 300V / CAT III 600 V Pollution degree 2 IEC 61010-2-034, IEC 61557-1,2,3,4,5,6,7,10 IEC 60529(IP40), IEC 61326(EMC) |
||||||
Communication interface | USB, Bluetooth® 5.0 | ||||||
Power source | LR6 (AA) (1.5V) ×8 | ||||||
Communication interface | USB | ||||||
Dimension / Weight | 136(L) × 235(W) × 114(D) mm / 1350g (including batteries) | ||||||
Accessories | Mains test lead*1 7281 (Test leads with remote control switch) 7246 (Distribution board test lead) 7228A (Earth resistance test leads) 8041 (Auxiliary earth spikes[2 spikes/1 set]) 9084 (Soft case) 9142 (Carrying case) 9151 (Shoulder strap) 9199 (Shoulder pad) LR6(AA) × 8 Instruction manual Calibration certificate |
||||||
Optional Accessories | 8212-USB (USB adapter) 8259 (Adapter for measurement terminal) 7272 (Precision measurement cord set) 8017A (Extension prod long) 8602 (EVSE ADAPETER) |
Please download “KEW Report(software)” from here.
*1 7187A:British plug, 7218A:(EU)European SCHUKO plug, 7221A:(SA)South african plug, 7222A:(AU)Australian plug
For no trip LOOP L-PE testing on all RCDs.
With 3 wire (L, N, PE), to get the best accuracy readings.
With 2 wire only, very useful in case of no Neutral (i.e. 3-phase motor lines).
High test current range of 2Ω with 0.001Ω resolution.
Zs Limit compares the values required by Electrical Installations Standard with measured results.
The verification of safety requirement on an electrical installation is simplified by using Zs/Ra Limit function. This function will automatically check if the measured loop impedance for TN (or earth loop for TT) is low enough to trip (disconnect) the MCB / Fuse / RCD giving the result of PASS or FAIL on the display.
SPD (Surge Protection Device) which contains varistor can be tested measuring the tripping voltage without damage it.
PAT test (PAT = Portable Appliance Tester) It is possible to check the insulation resistance and earth bond continuity of portable appliances for class I and II.
Use the application KEW Smart Advanced to improve work efficiency.
KEW 6516BT can trancfer the test data toa Tablet or Smartphone via Bluetooth.
Such test data can be saved, shared and sent by email.
Measurement Data Managemant Application “KEW Smart Advanced”