MODEL 2300R

Out of Stock

MODEL 2300R

• True RMS reading is an essential feature for accurate measurement.
• “Non Contact” voltage function indicates the presence of AC voltage by warning the user with an audible signal.
• Set the DC current range to zero in one touch with the Zero Adjust function.

Product Catalogue

TRUE RMS   ?10   MAX100A   DCACA   NCV   DATAHOLD    AutoPowerOff

LKR 54,692

Out of stock

Easy Payment Plans

Sampath Bank Payment Plans
The installment payment calculations now include the VAT(18%) amount of Rs.9844.47, bringing the total cost to Rs.64535.97. All displayed amounts reflect this inclusive pricing for complete transparency.
Month(s) Handling Fee (%) Monthly (Approx) Total (Approx)
3 0.00% 21,511.99 64,535.97
6 0.00% 10,756.00 64,535.97
Commercial Bank Payment Plans
The installment payment calculations now include the VAT(18%) amount of Rs.9844.47, bringing the total cost to Rs.64535.97. All displayed amounts reflect this inclusive pricing for complete transparency.
Month(s) Handling Fee (%) Monthly (Approx) Total (Approx)
6 0.00% 10,756.00 64,535.97

KEW FORK 2300R can be used in crowded connection boxes, where cables are very short, and space is too limited to clamp cables using with a traditional clamp meter.

True RMS (Root Mean Square) Value Measurement

When load current is not affected by the distortion, both averaging value type and true RMS (root mean square) type clamp meters show the almost same value of about 10A with constant wave-form as the above display samples. However, when load current is affected by some distortions such as inverter, etc...,averaging value type clamp meter indicates 5.5A instead of 9.7A and true RMS type clamp meter indicates 7.9A instead of 9.7A with irregular wave-form. Accordingly, true RMS type clamp meter is recommendable for the measurement of the equipment with inverter control devices.
Due to the use of thyristors, inverters and other energy-saving controllers in recent electric wiring, current waveforms often include harmonic components and are distorted compared to sinusoidal waves (50/60Hz).
The Kyoritsu True RMS value tester is able to measure distorted waveforms using true RMS since waveforms are being internally calculated continuously. In contrast, when measurements are made with a averaging value tester, errors are generated in the measurement value because the tester cannot continuously track distorted waveforms.

(Compared to the true RMS value tester, measurement values for the averaging value generate more than 30% errors in some cases.)

Current measurement AC A 0 to 100.0A ±2.0%rdg±5dgt (50/60Hz)
DC A 0 to ±100.0A ±2.0%rdg±5dgt
Crest factor 2.5
Non contact voltage Detect AC voltage without contacting with socket wire
During voltage detection, "Hi" flashes and a buzzer sounds
Maximum digit 1,049
Conductor size Max Ø10mm
Safety Standard IEC 61010-1 CAT III 300V Pollution degree 2
Power source R03 (AAA) × 2 (Auto power off: approx.10 minutes)
*Continuous measuring time: AC A approx. 46 hours DC A approx. 52 hours
Dimensions 161.3(L) × 40.2(W) × 30.3(D)mm
Weight 110g (with batteries)
Included Accessories 9113 (Carrying Case)
R03 (AAA) × 2
Instruction Manual

Reviews

There are no reviews yet.

Be the first to review “MODEL 2300R”

Your email address will not be published. Required fields are marked *

Related Products

Out of stock

SimpliFiber® Pro Optical Pow...

Out of stock

FI-500 FiberInspector™ Micro...

Out of stock

Fiber Optic Cleaning Kits

Out of stock

OptiFiber® Pro OTDR Family

Out of stock

Fiber QuickMap™

Out of stock

FI-7000 FiberInspector™ Pro

Out of stock

Fluke Networks Pro3000™ Tone...

Out of stock

Fluke Networks LinkIQ™ Cable...

Out of stock

Fluke Networks Industrial Et...

Out of stock

Fluke Ti480 PRO Infrared Cam...

Product Search

Request Quote